Dwyer 626 Precision Pressure Transmitter

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xWetted Materials | Type 316 SS | Accuracy 626 | 0.25% FS |
---|---|---|---|
Temperature Limits | 0 To 200°F (-18 To 93°C). | Thermal Effect 626 | ±0.02% FS |
Output Signal 2-wire | 4 To 20 MA | Response Time | 300 Msec |
Highlight | Dwyer 626 Precision Pressure Transmitter,Precision Pressure Transmitter 20mA,20mA dwyer pressure transmitter 626 |
Service: | Compatible gases and liquids. | |
---|---|---|
Wetted Materials: | Type 316L SS. | |
Accuracy: | 626: 0.25% FS; | |
Temperature Limit: | 0 to 200°F (-18 to 93°C). | |
Compensated Temperature Range: | 0 to 175°F (-18 to 79°C). | |
Thermal Effect: | ±0.02% FS/°F. (includes zero and span). | |
Pressure Limits: | See Catalog page. | |
Power Requirements: | 10 to 30 VDC | |
Output Signal: | 4 to 20 mA, | |
Response Time: | 300 ms. | |
Loop Resistance: | 0 to 1000 Ω max. R max = 50 (Vps-10) Ω (4 to 20 mA output), 0 to 1250 Ω max. Rmax = 50(Vps-10) Ω (4 to 20 mA output with -CB option), 5 KΩ (0 to 5, 1 to 5, 1 to 6, 0 to 10, 2 to 10, 0.5 to 4.5 VDC output). | |
Stability: | 1.0% FS/year (Typ.). | |
Current Consumption: | 38 mA maximum (for 4 to 20 mA output); | |
Enclosure Rating: | NEMA 4X (IP66). | |
Mounting Orientation: | Mount in any position. | |
Weight: | 10 oz (283 g). | |
Agency Approvals: | CE, NSF, UL. |
Series 626 Industrial Pressure Transmitters
The SERIES 626 AND 628 Pressure Transmitters monitors the pressure of compatible gases and liquids with 0.25% FS accuracy for 626 models or 1.0% FS accuracy for 628 models. The design employs a pressure sensor that can convert a single positive pressure into a standard 4 to 20 mA output or field selectable voltage output. The terminal block, as well as a zero adjustment button, are easily accessed under the top cover. The Series 626 and 628 are designed to meet NEMA 4X (IP66) construction.
Specification
Wetted Materials: | Type 316 SS |
Accuracy: | 0.25% FS |
Temperature Limits: | 0 to 200°F (-18 to 93°C). |
Output Signal: | 2-wire: 4 to 20 mA; |
Response Time: | 300 msec. |
Weight: | 10 oz (283 g). |
INSTALLATION
1. Location: Select a location where the temperature of the unit will be between 0 and 175°F (-18 to 79°C). Distance from the receiver is limited only by total loop resistance. The tubing feeding pressure to the instrument can be practically any length required, but long lengths will increase response time slightly.
2. Position: The transmitter is not position sensitive. However, all standard models are originally calibrated with the unit in a position with the pressure connection downward. Although they can be used at other angles, for best accuracy, it is recommended that units be installed in the position calibrated at the factory.
3. Pressure Connection: Use a small amount of plumber’s tape or other suitable sealants to prevent leaks. Be sure the pressure passage inside the port is not blocked.
4. Electrical Connections Wire Length — The maximum length of wire connecting the transmitter and receiver is a function of wire size and receiver resistance. Wiring should not contribute to more than 10% of the receiver resistance to total loop resistance. For extremely long runs (over 1000 ft or 305 m), choose receivers with higher resistance to minimize the size and cost of connecting leads. Where wiring length is under 100 feet (30.5 m), wire as small as 22 AWG can be used. CURRENT (4 to 20 mA) OUTPUT OPERATION An external power supply delivering 10 to 35 VDC with minimum current capability of 40 mA DC (per transmitter) is required to power the control loop. See Figure 1 for connection of the power supply, transmitter, and receiver. The range of appropriate receiver load resistance (RL) for the DC power supply voltage available is expressed by the formula:
RL Max = Vps – 10 /20 mA DC
Shielded cable is recommended for control loop wiring. Electrical connections to the Series 626/628-CB pressure transmitters are made to the terminal block located inside the housing. Remove the screws and lift off the cover. Lift off the terminal block for wiring. Wire as show in Figure 1 or 2. Use Figure 1 for current output connection. Use Figure 2 for current output with optional LCD display. If ordering pre-wired cable, black wire is negative (-) and red wire is positive (+)
VOLTAGE (0 to 5, 1 to 5, 0 to 10, or 2 to 10 V) OUTPUT OPERATION To select the voltage output that is going to be used, configure the DIP switches according to the Figure 4 below. Power must be cycled whenever dip switches are changed to select output.
MAINTENANCE/REPAIR Upon final installation of the Series 626/628-CB Industrial Pressure Transmitter, no routine maintenance is required. The Series 626/628-CB is not field serviceable and is not possible to repair the unit. Field repair should not be attempted and may void warranty.
WARRANTY/RETURN Refer to “Terms and Conditions of Sale” in our catalog and on our website. Contact customer service to receive a Return Goods Authorization number before shipping the product back for repair. Be sure to include a brief description of the problem plus any additional application notes
FAQ
We are based in Shaanxi, China, start from 2019,sell to Domestic Market(70.00%),Mid East(30.00%). There are total about 11-50 people in our office.
2. how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
3.what can you buy from us?
transmitter,flowmeter,positioner,gauge,PLC
4. why should you buy from us not from other suppliers?
We have many famous brands for transmitter,flowmeter,positioner PLC/DCS products,we supply the best price and delivery time also the best after sale service.
5. what services can we provide?
Accepted Delivery Terms: FOB,CFR,CIF,EXW;
Accepted Payment Currency:USD,EUR;
Accepted Payment Type: T/T,L/C,MoneyGram,PayPal,Western Union,Cash;
Language Spoken:English,Chinese