-
Differential Pressure Gauge
-
Digital Pressure Gauge
-
Stainless Steel Pressure Gauge
-
Precision Pressure Transmitter
-
Programmable Logic Controller
-
Float Level Switch
-
Pneumatic Valve Positioner
-
Temperature Transmitter Sensor
-
Hart Field Communicator
-
Solenoid Valve
-
Control Valves
-
High Accuracy Flow Meter
-
Submersible Water Pump
-
Pressure Transmitter Manifold
-
Ultrasonic Level Meter
-
Voltage Current Power Meter
Magnesense Digital Pressure Gauge 40mA
Place of Origin | USA |
---|---|
Brand Name | Dwyer |
Certification | CCC CE |
Model Number | MS2-W021 |
Minimum Order Quantity | 1 |
Price | $70-$95/pc |
Packaging Details | Strong carton Packing with export standard. If each model more than 300PCS can make colored strong carton |
Delivery Time | 14 work days |
Payment Terms | L/C, T/T, Western Union, D/P |
Supply Ability | 10000 Piece/Pieces per Month |

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xWarranty | 1 Year | Customized Support | OEM, ODM |
---|---|---|---|
Application | Industries | Current Consumption | 40 MA Max. |
Electrical Entry | 1/2" NPS Thread | Stability | ±1% / Year FSO |
Highlight | Magnesense Digital Pressure Gauge,Digital Pressure Gauge 40mA,Industrial Pressure Gauge 40mA |
Type | digital tyre pressure gauge accuracy | |
---|---|---|
Type | digital pneumatic pressure gauge | |
Type | calibrated digital pressure gauge | |
Type | digital water pressure gauge |
MS2 Series Magnesense Differential Pressure Transmitter-Dwyer
The SERIES MS2 Magnesense® II Differential Pressure Transmitter combines the proven stable Hall Effect sensing technology of our original Series MS with additional features to reduce installation time and simplify ordering. In this second generation transmitter, we have added additional field selectable pressure ranges so that each model can have four selectable ranges along with four additional bidirectional ranges. When using the pluggable integral display or the portable remote display tool, both Metric and English engineering units can be selected via on board dip switches. Dual current and voltage outputs allow users to simultaneously take either a current or voltage output to their building controller and have a local test circuit for verification of the output reading. The voltage output can be selected to be either 0 to 5 VDC or 0 to 10 VDC, while the current is always 4 to 20 mA. Both the current and voltage output can also be inverted. The MS2 can also be ordered with either a BACnet® or MODBUS® Communications protocol output that will allow the transmitters to be daisy-chained together.
Like the original Series MS, the second generation transmitter can be used as a linear pressure output or a linear velocity output with the square root extraction done in the transmitter. Additional parameters have been included to expand the square root capability to include flow measurements.
BACnet® and Modbus® Communications protocol recommend limiting the number of nodes in any segment to 32. Therefore, the transceiver may be rated at one unit load. Fractional loads are also acceptable. The MS2 accounts as an eighth of a load on the MSTP network.
Voltage Output: Min. load resistance 1 kΩ.

|