DT4256 TRMS DMM 1000V AC/DC 11 Functions 10A Direct Input Standard Style Corded Electric Power Source

Place of Origin china
Brand Name Hioki
Certification CE
Model Number DT4256
Minimum Order Quantity 1
Price USD$110
Packaging Details carton
Delivery Time in stock
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability 500pcs

Contact me for free samples and coupons.

Whatsapp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Brand Hioki Model DT4256
Power Source Corded Electric Style Standard
Highlight

10A Direct Input TRMS DMM

,

11 Functions TRMS DMM

,

1000V AC/DC TRMS DMM

Leave a Message
Product Description
DC Voltage range 600.0 mV to 1000 V, 5 ranges
Basic accuracy: ±0.3 % rdg. ±3 dgt.
AC Voltage range 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz
Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
AUTO AC/DCV Yes
Resistance range 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±3 dgt.
DC Current range 60.00 mA to 10.00 A, 4 ranges,
Basic accuracy: ±0.9 % rdg. ±3 dgt.
AC Current range 600.0 mA to 10.00 A, 3 ranges,
Basic accuracy 40 - 500 Hz : ±1.4 % rdg. ±3 dgt.
(True RMS, crest factor 3, 40 Hz to 1 kHz)
AC Current range
(use with Clamp on probes)
10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 - 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3)
Voltage detection
(50/60 Hz)
Hi: AC40 V to 600 V, Lo: AC80 V to 600 V
Capacitance range 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt.
Frequency range 99.99 Hz (5 Hz or more) to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage and current),
Basic accuracy: ±0.1 % rdg. ±1 dgt.
Continuity check Continuity threshold [ON]: 25 Ω or less (Indicate buzzer sound, red LED),
[OFF]: 245 Ω or more, Response time: 0.5 ms or more
Diode test Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less,
Threshold of forward voltage: 0.15 V to 1.5 V
Other functions Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option)
Display Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph
Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s )
Power supply LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF)
Dimensions and mass 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D,
390 g (13.8 oz) (including batteries and holster)
Included accessories Test lead L9207-10* ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4
* Replaced by the probe L9300 starting with batches manufactured in March, 2025.